Quadro Manual II: Administrator's Guide Administrator’s Menus
Quadro2x, 2xi, Quadro4x, 4xi, Quadro16x, 16xi; (SW Version 5.2.x) 95
The Tunnels to Slave Devices page consists of a table where
he SIP Tunnel Name text field requires the tunnel name for
nding connection. System suggests you to start the
IP tunnel name with the “SIP_Tunnel_” words, according to the
utomatic prefix used for the SIP tunnels on the Quadro,
owever this is not mandatory.
he User Name text field requires the authentication user
ame. The field in front of this text field displays the default non-
r SIP tunnels: “SIPTunnel_”.
nnel
when the
slave devices are listed with the corresponding authentication
parameters.
Add functional button leads to the Add Entry page where a new
slave device parameters needs to be provided.
The Add Entry page consists of the following components:
T
the correspo
S
a
h
T
n
editable prefix fo
The Password text field requires the authentication password.
Please Note: The User Name and Password should match
both on master and slave Quadros for the successful SIP tu
establishment.
The Symmetric NAT checkbox should be selected
slave Quadro is located behind the symmetrical NAT.
Fig. II-165: SIP Tunnel Settings – Tunnels to Slave Devices page
Fig. II-166: SIP Tunnel Settings – Tunnels to Slave Devices – Add Entry page
igured.
The Enable Tunnels to Master Devices checkbox enables the
Quadro as a slave device and allows connecting to the master
Quadro via SIP tunnel. When this checkbox is enabled the
Tunnels to Master Devices table needs to be conf
The link Tunnels to Master Devices moves you to the page
where a list of master devices needs to be defined.
Fig. II-167: SIP Tunnel Settings – Tunnels to Master Devices page
he Tunnels to Master Devices page consists of a table where master devices are listed with the corresponding authentication parameters.
on leads to the Add Entry page where a new master device parameters needs to be provided.
he following components:
The Tunnel Name text field requires the SIP tunnel name for
art the
e
Plea
both
esta
T
Add functional butt
The Add Entry page consists of t
The Enable Registration checkbox selection is used to enable
the registration to the corresponding master device.
the corresponding connection. System suggests you to st
P tunnel name with the “SIP_Tunnel_” words, according to theSI
automatic prefix used for the SIP tunnels on the Quadro,
however this is not mandatory.
The User Name text field requires the authentication user
name. The field in front of this text field displays the default non-
editable prefix for SIP tunnels: “SIPTunnel_”.
Th Password text field requires the authentication password.
se Note: The User Name and Password should match
on master and slave Quadros for the successful SIP tunnel
blishment.
Fig. II-168: SIP Tunnel Settings – Tunnels to Master Devices – Add Entry page
he Master device IP text field requires the IP address of the master device.
he Registration Date/Time field displays the time and the date of last registration on the master’s device.
T
The Master device port text field requires the SIP port number of the master device.
The Registration State field displays information whether the slave device is registered on the master or not.
T
Komentarze do niniejszej Instrukcji